TQ902 vs TQ402: Order Code Changes, Replacement & Application Guide for Proximity Sensors

زمان: September 11, 2026
TQ902 111-902-000-011 and TQ402 111-402-000-013 part numbers are always by a lengthy order number string. These ordering numbers are quite important, as each code represents the configuration of the sensor. From these codes, the operating environment, body length, unthreaded length, cable protection and total system length can be read directly. 

However, with the upgrade from TQ402 to TQ902, some ordering codes have also changed accordingly. The environment code A is simplify, since it may be hard to determine which explosive zones the sensors will be installed in by the clients.  The codes for Body length(C), unthreaded length(D), integral cable length(E) and flexible hose length(G) are numerical and the units all converted to mm. The cable protection code F has been simplify as well, reduce the options down to 5. Unthreaded length code D is changed from D000 to D2, with a new minimum value of 2 mm.

The below form shows the difference of the ordering number:

Coding

TQ902 111-902-000-011

TQ402

111-402-000-013

Comments

A:Environment

A5

A2

A unique coding for all Ex certifications

B:Body thread

B1

B1

——

C:Body length

C20

C020

Numerical value in mm

D: Unthreaded length

D5

D005

Numerical value in mm

E: Integral Cable

E5000

EO50

Numerical value in mm

F:Protection

F2

F1

A unique cable profection

G: Flexible hose length

G3000

G030

Numerical value in mm

H: Total System length

H05

H05

——



For example: TQ402 111-042-000-013 A3-B6-C050-D000-E100-F1-G100-H10 upgrade to TQ902 is 111-902-000-011 A5-B6-C50-D2-E10000-F2-G10000-H10.

Q&A:
1. Can the TQ902 fully replace the TQ402?
Yes, TQ902 is form, fit and functionally equivalent replacement. It meet or exceed the performance of TQ402.

2. What are the application scenarios for the TQ902?
For non‑contact measurement of shaft relative vibration and axial gap/position on steam, gas, hydraulic turbines, alternators, turbocompressors and pumps.

3. Does the TQ902 intergral cable length equal the total system length?
The Total system length (H) = Integral cable length (E) + EA 402 extension cable length.

برای ما پرس و جو ارسال کنید

برای ما پرس و جو ارسال کنید
اگر به محصولات ما علاقه مند هستید و می خواهید جزئیات بیشتری بدانید، لطفاً در اینجا پیام بگذارید، ما در اسرع وقت به شما پاسخ خواهیم داد.